RIGOL · DIGITAL LOGIC PROBES

Logic Analyzer Probes

Expand your oscilloscope's capabilities with multi-channel digital signal acquisition. RIGOL logic analyzer probes connect digital signals to compatible RIGOL oscilloscopes for real-time logic capture, timing analysis and embedded-system debugging.

16-Channel Options 4-Channel Option Digital Signal Analysis
RIGOL PLA2216 logic analyzer probe system
RIGOL Logic Analyzer Probe · PLA2216 series
16 CHMulti-channel models
4 CHPLA3204 model
5 nsMinimum pulse width*
±40 VMaximum input voltage*
PLA2216 active logic probe cable and lead assembly
DIGITAL SIGNAL CAPTURE

Turn your oscilloscope into a mixed-signal test platform.

Logic analyzer probes bring digital signals into compatible mixed-signal oscilloscopes, allowing engineers to observe multiple logic channels alongside analogue waveforms and investigate timing relationships between signals.

✓Multi-channel digital signal acquisition
✓Digital and analogue waveform correlation
✓Adjustable logic threshold settings on supported scopes
✓Flexible signal leads and grabber accessories
✓Embedded-system troubleshooting
✓Model-specific oscilloscope compatibility
LOGIC ANALYSIS CAPABILITIES

See more than one signal at a time.

Capture digital activity across multiple channels and investigate how signals interact throughout your design.

▥

Multi-Channel Capture

Monitor multiple digital signals simultaneously. Select a 16-channel or 4-channel model according to your test requirements.

⌁

Timing Analysis

Observe digital transitions and timing relationships between channels to investigate signal sequencing and logic behaviour.

±

Adjustable Thresholds

Set logic threshold levels on compatible oscilloscopes to suit the digital signal family being measured.

⌖

Flexible Connections

Use individual signal leads and grabber clips to connect the probe to circuit test points.

◫

Mixed-Signal Debugging

Correlate digital channels with analogue waveforms on supported mixed-signal oscilloscopes.

⚙

Model-Specific Integration

Choose the probe designed for your oscilloscope family and its digital input interface.

RIGOL LOGIC PROBE FAMILY

Choose the right logic analyzer probe

RIGOL offers four logic probe models for different oscilloscope platforms and channel requirements.

16-Channel Active Probe

PLA2216

16 Channels

Designed for MSO5000 and DHO900/S series oscilloscopes. Includes 20 signal leads and 20 grabbers.

Enquire about PLA2216 →
16-Channel Logic Probe

RPL2316

16 Channels

Logic analyzer probe listed for MSO4000 and MSO2000A oscilloscope families.

Enquire about RPL2316 →
16-Channel Logic Probe

RPL1116

16 Channels

Logic probe designed for the MSO1000Z oscilloscope family.

Enquire about RPL1116 →
4-Channel Active Probe

PLA3204

4 Channels

Quad-channel logic analyzer probe listed for MHO/DHO5000 and MHO2000 families.

Enquire about PLA3204 →
TECHNICAL REFERENCE

PLA2216 specifications

Detailed specifications from the RIGOL PLA2216 Active Logic Probe User Guide.

ParameterSpecification
Input channels16 digital channels (D0–D15)
Channel groupsD0–D7 and D8–D15
Threshold range±15 V
Threshold accuracy±(100 mV + 3% of threshold setting)
Maximum input voltage±40 V peak
Maximum input dynamic range±10 V + threshold setting
Minimum voltage swing500 mVpp
Minimum detectable pulse5 ns
Input impedanceApproximately 101 kΩ
Input capacitanceApproximately 8 pF
Main cable lengthApproximately 90 cm
Input lead lengthApproximately 25 cm
Operating temperature0°C to 50°C
Operating humidity0 to 80% RH

PLA2216 specifications are shown as a reference and should not be assumed to apply to the other models. Refer to the corresponding model user guide for RPL2316, RPL1116 and PLA3204 specifications.

OSCILLOSCOPE COMPATIBILITY

Match the probe to your oscilloscope.

Selecting the correct probe is essential for enabling the digital input and logic analysis functions of your oscilloscope.

Probe ModelChannel CountListed Oscilloscope Compatibility
PLA221616MSO5000, DHO900/S
RPL231616MSO4000, MSO2000A
RPL111616MSO1000Z
PLA32044MHO/DHO5000, MHO2000

Check the digital input

Confirm that your oscilloscope has the required digital signal input or supported interface.

Verify the probe model

Check the model-specific compatibility list before ordering a logic analyzer probe.

Confirm accessories

Check included leads, grabbers, cable assemblies and any additional connection accessories.

APPLICATION AREAS

Where logic analyzer probes are used

Useful for embedded development, digital electronics validation and troubleshooting complex digital systems.

▦

Embedded Systems

Investigate digital control signals and interactions between embedded system components.

⌘

Digital Communication

Observe timing and logic activity in digital communication interfaces.

▤

Microcontroller Testing

Monitor GPIO activity, control lines and digital state transitions.

⚡

Hardware Debugging

Find timing issues and unexpected digital transitions during circuit debugging.

⌁

Product Validation

Capture digital behaviour during engineering verification and validation.

◎

R&D Laboratories

Support digital circuit analysis and mixed-signal development workflows.

NEED HELP SELECTING A LOGIC PROBE?

Find the right RIGOL logic analyzer probe.

Contact our team for model selection, oscilloscope compatibility and product enquiries.

Enquire Now →