RF AMPLIFIERS / EMC IMMUNITY TESTING
TEKBOX / TBMDA-BCI100

Modulated Wideband Power Amplifier

A high-power RF amplifier designed for conducted immunity testing with Bulk Current Injection (BCI) probes. Covering 1 MHz to 400 MHz, it combines wideband amplification with built-in AM and PM modulation.

ENQUIRE ABOUT THIS PRODUCT →
Tekbox TBMDA-BCI100 modulated wideband RF power amplifier
1–400 MHzFrequency range
110 WUp to 1 dB compression point
52 dBTypical small-signal gain
AM / PMBuilt-in modulation
TBMDA-BCI100 front panel and RF connectors
PRODUCT OVERVIEW

Wideband RF amplification for BCI testing

The TBMDA-BCI100 provides the bandwidth and modulation required for conducted immunity testing using BCI probes in accordance with ISO 11452-4.

It can be driven by a signal generator or a spectrum analyser tracking generator. Its typical 52 dB small-signal gain enables the amplifier to reach high output levels with a 0 dBm tracking-generator signal.

  • 1 MHz to 400 MHz operating frequency range
  • Up to 110 W at the 1 dB compression point
  • Built-in AM and PM modulation modes
  • Compatible with spectrum analyser tracking generators
  • VSWR monitoring
  • 50Ω N-female RF input and output
KEY FEATURES

Engineered for immunity test applications

Combining RF power, integrated modulation and monitoring features in one amplifier for EMC pre-compliance test environments.

01 / RF POWER

High output capability

Up to 110 W at the 1 dB compression point across the 1 MHz to 400 MHz operating band, according to the manufacturer's product description.

02 / BANDWIDTH

Wide frequency coverage

Designed for 1 MHz to 400 MHz conducted immunity testing. Operation from 100 kHz to 1 MHz is possible at reduced output power.

03 / MODULATION

Integrated AM and PM

Built-in 1 kHz, 80% AM and two pulse-modulation modes for immunity test signal generation.

04 / GAIN

52 dB typical gain

High small-signal gain allows use with a spectrum analyser tracking generator providing a 0 dBm signal.

05 / MONITORING

VSWR monitoring

Front-panel VSWR monitoring helps identify an output mismatch condition during operation.

06 / CONNECTIVITY

50Ω RF interfaces

N-female RF input and output connections for compatible RF signal sources and test accessories.

BUILT-IN MODULATION

Multiple modulation modes in one amplifier

Select the required operating mode using the front-panel controls. The amplifier also supports CW operation with modulation disabled.

CWContinuous-wave amplification with modulation switched off.
1 kHz AMAmplitude modulation at 1 kHz with 80% modulation depth.
1 kHz PMPulse modulation at 1 kHz with 50% duty cycle.
217 Hz PMPulse modulation at 217 Hz with 12.5% duty cycle, intended to simulate mobile-phone TDMA noise.
APPLICATIONS

For conducted and radiated immunity testing

The TBMDA-BCI100 is designed for RF power amplification in EMC test setups.

APPLICATION / 01

Bulk Current Injection

Drive BCI probes for conducted immunity testing according to ISO 11452-4.

APPLICATION / 02

Near-Field Probes

Provide wideband RF amplification for radiated immunity test setups using near-field probes.

APPLICATION / 03

TEM Cells

Use as a wideband RF power amplifier in radiated immunity testing with TEM cells.

TECHNICAL DATA

TBMDA-BCI100 specifications

Key electrical, mechanical and operating specifications published by Tekbox Digital Solutions.

Product modelTBMDA-BCI100
Product typeModulated wideband RF power amplifier
Frequency range1 MHz – 400 MHz
Extended frequency operation100 kHz – 1 MHz, with reduced output power
1 dB compression pointUp to 110 W across the 1 MHz – 400 MHz range
Small-signal gain52 dB typical
Gain flatness1.5 dB typical, 1 MHz – 400 MHz, Pin = -3 dBm
Input / output impedance50Ω
RF connectorsN-female input and output
Maximum input power+0 dBm
AM modulation1 kHz, 80% modulation
PM modulation1 kHz, 50% duty cycle
PM modulation217 Hz, 12.5% duty cycle
AM frequency tolerance±20%
PM frequency tolerance±20%
PM duty-cycle tolerance50% ±10% at 1 kHz; 12.5% ±20% at 217 Hz
Supply voltage100–120 VAC or 200–240 VAC, 50/60 Hz
Power consumption350 W at 220 V
Operating temperature-20°C to 50°C
Dimensions48.5 × 31 × 13.5 cm
Weight10.5 kg

Output power varies with frequency and operating conditions. The 110 W figure refers to the maximum 1 dB compression point, not a guaranteed constant output across every frequency.

OUTPUT PERFORMANCE

Typical output power across frequency

Manufacturer-published typical maximum output power values measured with a 0 dBm input signal. These figures are not the 1 dB compression-point values.

FrequencyTypical maximum outputPower
1 MHz50.7 dBm117.5 W
10 MHz50.7 dBm117.5 W
50 MHz50.8 dBm120.2 W
100 MHz50.7 dBm117.5 W
150 MHz50.8 dBm120.2 W
200 MHz50.5 dBm112.2 W
250 MHz50.5 dBm112.2 W
300 MHz50.6 dBm114.8 W
350 MHz50.6 dBm114.8 W
400 MHz49.5 dBm89.1 W

Typical values from the manufacturer's published specifications. Maximum output power and 1 dB compression point are different measurements.

PRODUCT DETAILS

Front and rear panel views

View the amplifier's RF connections, modulation controls, status indication and power input.

IMPORTANT OPERATING INFORMATION

RF output protection

Follow the manufacturer's operating guidance when connecting the amplifier to test accessories or unknown loads.

Load protection: Open-circuit or short-circuit output operation is not recommended and may damage the output transistor. When driving near-field probes, current probes or loads with unknown impedance, Tekbox highly recommends inserting an attenuator of at least 3 dB at the amplifier output to protect the output stage.
PRODUCT ENQUIRY

Need an RF amplifier for EMC immunity testing?

Contact our team for product details, availability and quotation.

CONTACT SALES →