EMC TEST & MEASUREMENT
TEKBOX / TBL05100-1C

5µH Line Impedance Stabilisation Network

A configurable 100A LISN designed for conducted-emissions measurements across a range of EMC testing standards. Provides a defined supply impedance and an RF output for measurement receivers and spectrum analysers.

ENQUIRE ABOUT THIS PRODUCT →
Tekbox TBL05100-1C 5 microhenry LISN
5µHInductance
100AMaximum current
10kHz–400MHzCharacterised frequency range
2.7kgProduct weight
TBL05100-1C front panel showing RF output and terminals
PRODUCT OVERVIEW

Reliable conducted-emissions measurements

The TBL05100-1C is inserted into the supply line of the equipment under test (EUT). Its 5µH inductor decouples the source from the EUT, while conducted noise at the EUT supply terminals can be monitored through the RF output connector.

The unit is factory configured for 50Ω // 5µH + 1Ω. Internal jumper settings allow alternative 50Ω // 5µH configurations for other test requirements.

  • Single-path configurable LISN topology
  • RF output for spectrum analysers and measurement receivers
  • 100A maximum current capability
  • High-current source and EUT connections
  • Grounding provisions for ground-plane mounting
KEY FEATURES

Designed for demanding EMC test environments

Configurable impedance, high-current connections and a dedicated RF measurement output make the TBL05100-1C suitable for a variety of conducted-noise test setups.

01 / IMPEDANCE

Configurable topology

Factory configured for 50Ω // 5µH + 1Ω, with an alternative 50Ω // 5µH configuration selectable using the internal high-current jumper.

02 / MEASUREMENT

Dedicated RF output

Monitor conducted noise at the EUT supply terminals through the N-female RF connector using a spectrum analyser or measurement receiver.

03 / CURRENT

100A capability

Designed for high-current supply-line testing, with a maximum current rating of 100A. Refer to the manufacturer's thermal characteristics for operating conditions.

04 / FREQUENCY

Wide test coverage

Characterised frequency range from 10kHz to 400MHz for conducted-emissions test applications.

05 / CONNECTION

High-current terminals

M8 binding-post connections for source and EUT, with dedicated earth connection and RF output.

06 / FLEXIBILITY

Multiple test standards

Configurable setup supports several automotive, military, industrial and aerospace EMC test requirements.

TEST STANDARD COMPATIBILITY

One platform for multiple EMC requirements

The TBL05100-1C supports impedance configurations associated with the following standards. The correct internal jumper and capacitor configuration must be selected for the intended test.

CISPR 16-1-2 CISPR 25 MIL-STD-461G DO-160 ISO 11452-4 ISO 7637-2
Configuration note: The unit is factory configured for 50Ω // 5µH + 1Ω. Other configurations require changing the internal high-current jumper. For DO-160, an external 10µF capacitor is required. Check the manufacturer's manual for the exact setup before testing.
TECHNICAL DATA

TBL05100-1C specifications

Key technical specifications as published by Tekbox Digital Solutions.

Product modelTBL05100-1C
Product type5µH Line Impedance Stabilisation Network (LISN)
TopologySingle path, configurable
Impedance configurations50Ω // 5µH + 1Ω; 50Ω // 5µH
Characterised frequency range10kHz – 400MHz
Maximum current100A
Maximum operating voltage0–500V AC at 50/60Hz; 250V AC at 400Hz; 1000V DC
Absolute maximum internal component rating1500V DC
DC resistanceLess than 5mΩ, Source+ to EUT+; less than 5mΩ, Source− to EUT−
RF connectorN-Female
EUT connectorM8 binding post, 100A, 1kV
Source connectorM8 binding post, 100A, 1kV
Earth connection8mm earth stud with wing nut
JumperHarwin D3087-98
Dimensions300 × 150 × 150mm
Weight2.7kg

Specifications are based on the manufacturer's published product information. Refer to the latest manual for operating conditions, configuration details and safety requirements.

ACCESSORIES

Optional accessories

Additional accessories are available to support shielding and calibration requirements.

OPTIONAL / 01

TBST

Shielded tent for shielding-related test setups.

OPTIONAL / 02

TBSB

Shielded bag for shielding-related applications.

OPTIONAL / 03

TBL05100-1C-CAL

Calibration kit for the TBL05100-1C LISN.

APPLICATIONS

For conducted-noise testing and EMC development

The LISN provides a defined impedance at the equipment under test and a measurement point for conducted-noise evaluation.

  • EMC pre-compliance testing
  • Automotive conducted-emissions measurements
  • Military equipment EMC testing
  • Industrial electronic equipment testing
  • Aerospace equipment test setups
  • Common-mode and differential-mode noise measurements using two LISNs and the Tekbox LISN Mate
Tekbox TBL05100-1C source input and rear panel
PRODUCT ENQUIRY

Looking for the right LISN for your test setup?

Contact our team for product information, configuration guidance and quotation.

CONTACT SALES →